Common array manager - Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.

 
 Ce document est destiné à vous guider dans les étapes de base de l’installation du logiciel Sun Storage Common Array Manager d’Oracle. Si vous procédez à une mise à niveau à partir d’une ancienne version ou souhaitez obtenir des informations complémentaires, consultez le Sun Storage Common Array ManagerGuide d’installation et de ... . Flight from new york to paris

Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI). “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.This article documents Sun Storage 6580/6780 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and …Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated …Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.vi Sun StorageTek Common Array Manager Software Installation Guide • October 2006 Creating Initiators to Assign to Hosts 61 To Create An Initiator and Assign It To a Host: 61 Using the New Volume Wizard to Create and Map Volumes 62 To Use the New Volume Wizard to Create Volumes 62 About Volumes and the Default Domain or Partitioned …Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content,This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forSun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. Sun StorageTek[TM] Common Array Manager (CAM)には、Sun StorEdge[TM]、Sun StorageTek [TM]、StorageTek[TM]、Sun Storage[TM]アレイのサポート・ベースの構成およびログを収集する機能があります。これはブラウザまたはCLIインタフェースを使用して実行できます。 Storage Common Array Manager 6.9.0. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1vi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80 The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. %Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application.Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and …Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage Flexline 280 Array - Version Not Applicable and later All Platforms Goal. This article documents Sun StorageTek Flexline 280 (FLX280) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.9 [Release 6.0] Information in this document applies to any platform. Purpose. The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.9.Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and …Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400). Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... Goal. If you want to install Sun Storage Common Array Manager (CAM) in a Solaris 10 non-global zone, you first need to install Lockhart/Java Web Console in the Solaris 10 global zone, otherwise the installation of CAM fails with one or more of the following errors: The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. Sun Storage Common Array Manager Reports "SYSTEM_ERROR" During the Firmware Upgrade Process (Doc ID 1334772.1) Last updated on JUNE 21, 2019. Applies to: Sun Storage 6180 Array - Version Not Applicable and later Sun Storage 6540 Array - Version Not Applicable and later Sun Storage 6580 Array - Version Not … Instructions to download Common Array Manager (CAM). Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download. Click on "Search". This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forFrom Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Jan 1, 2023 · Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated Learn Cycle has been run. Cause Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a …Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download;Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] ...To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host. Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are …9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage 2530-M2 Array - Version Not Applicable and later Information in this document applies to any platform. Goal. Sun Storage 2500, 2500-M2, and 6000 arrays support Dynamic Volume Expansion (DVE). DVE is an operation that allows the user-visible …SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details …You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ...Goal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. …vi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more …xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release NotesTo Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details …This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User …Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content,Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated …Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and … Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... Overview. Sun StorageTek (TM) Common Array Manager is a Shareware software in the category Desktop developed by Sun StorageTek (TM) Common Array Manager. The latest version of Sun StorageTek (TM) Common Array Manager is currently unknown. It was initially added to our database on 10/30/2007.The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for … Ce document est destiné à vous guider dans les étapes de base de l’installation du logiciel Sun Storage Common Array Manager d’Oracle. Si vous procédez à une mise à niveau à partir d’une ancienne version ou souhaitez obtenir des informations complémentaires, consultez le Sun Storage Common Array ManagerGuide d’installation et de ... Overview of the Installation Process. Before you install the Common Array Manager software, you must do the following: Read the Sun StorageTek Common Array Manager Software Release Notes for any late-breaking information related to the installation of the array.; Install the array hardware per the hardware installation documentation that came …Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.

The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.. Google citation search

common array manager

This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Sun StorageTek Common Array Manager Software Installation Guide, Version 6.5.0: HTML: PDF: Sun StorageTek Array Administration Guide, Version 6.6.0: PDF: Sun StorageTek Common Array Manager User Guide for Open Systems: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide, Version 6.6.0: HTML: PDF: Sun … Title: Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x Author: Oracle and/or its affiliates Subject: This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manage 爀 猀漀昀琀眀愀爀攀⸀ 䤀昀 礀漀甀 愀爀攀 甀瀀最爀愀搀椀渀最 昀爀漀洀 愀 瀀爀攀瘀椀漀甀猀 瘀攀爀猀椀漀渀 漀爀 渀攀攀搀 ... From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser InterfaceIt is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400). このドキュメントの目的は、StorageTek、Sun StorEdge、Sun StorageTekおよびSun Storage アレイのディスク障害の症状のトラブルシューティングを支援することです。. 現象. Common Array ManagerまたはSANtricityが、「 Failed Hot Spare or Unassigned Drive(ホットスペアの失敗または ... 2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to … Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Common Array Manager Windows 7 Pro, CAM ver 6.9.0.16. Not sure, this might an appropriate forum for this question. I am afraid this question bears no relation to Oracle on Microsoft Windows - Installation, Configuration and Troubleshooting.Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Storage Common Array Manager 6.9.0. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1%Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) … Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide. .

Popular Topics