4 ton 410a piston size - The Goodman® GSZ13 heat pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life ...

 
 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ... . I in bubble letters graffiti

York still ships an orifice with the condenser; And a schrader for the evap in you use said piston. There is no standard for piston sizing. Each mfr does it their own way. Nordyne uses a 67 for a 3 ton 410 unit for example. ADP says 73 for 3 ton R22.This manual is also suitable for: View and Download Goodman GPH 14 SEER R-410A technical manual online. GPH 14 SEER R-410A Package Heat Pump Units. GPH 14 SEER R-410A heat pump pdf manual download. Also for: Gph1424h41ab, Gph1430h41ab, Gph1436h41ab, Gph1442h41ab, Gph1448h41ab, Gph1460h41ab.TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Downflow Insulation Kit ... For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit …Lennox Elite CH35, CH35-51C-2F, 4 Ton, Piston (R410A), Cased Aluminum Horizontal Evaporator Coil. Cat # : 10C38 ... 4 Ton . Metering Device. Piston (R410A) Product ...Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig...Size (tons) Nominal BTU/hr Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions ... 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER ... Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match, Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches. The CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-51/61C-6F-1 coil is built to high standards and is backed by ... The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA! Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil. CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit.Cabinet Finish 4 - R-410A only U Uncased P Cased - Painted C Cased - Unpainted Expansion Device Nominal Width or f Gas Furnace F Flowrater A - 14” Width D - 24.5” Width ... Tons Connection Piston Size* (in.) Ship Weight W H A Liquid Suction (lbs) CAUF3137B6 16½" 27" 25" 2½-3 ⅜" ¾" .071 53Piston fancoils are no longer offered in the 5 ton size; therefore none of the 5 ton outdoor models show an indoor piston size. 13 SEER “E” series split Heat Pumps: N4H3**(A,G)KE C4H3**GKE H4H3**GKE T4H3**GKE All models have the required R-410A indoor piston size printed on the outdoor unit rating plate. All models include one R-410A indoor ...4 physical data unit size 024 030 036 042 048 060 nominal capacity (ton) 2 2.5 3 3.5 4 5 shipping weight (lb) (kg) 312 142 333 151 334 152 388 177 407 185 475 215 compressor type scroll refrigerant r-410a refrigerant quantitiy (lb) quantity (kg) 6.3 2.9 9.8 3.1 6.8 3.1 7.7 3.5 9.0 4.1 12.0 5.4 outdoor metering device txv piston txv piston ...Bales of hay vary in size from 40 to 2,000 pounds. A three-string bale weighs around 100 pounds, and there are approximately 20 three-string bales in a ton. Round bales weigh 850 t...Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more.Refrigeration Type. R-410A. Cooling Efficiency (EER) UP TO 10.85. Phase. 3. Capacity Range (BTU) 37200-83000. [email protected] Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 °F (145 through 99 psig) 29 °F through 10 °F (97 through 64 psig) 9 °F through –10 °F (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System ...R-410A 2 Ton; R-22 1.5 Ton; Piston Size 53; Specifications Product Name: Piston #53 2T R410A Brand Name: ADP Item # 100000036 Weight: 1 lbs Length: 12 in Width: 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ... Standard size coils (1.5 to 5 tons) HP-A/C TXV R410A (non-bleed) Large Tonnage Coils . HP-A/C TXV R-22 (non-bleed) Large Tonnage Coils . TXV Large tonnage coils (Discontinued) ... standard R-22 and R-410A pistons listed above (100 pistons total) in a plastic case 176799800. 1; All piston models. Miscellaneous. Part Number. Qty. Used …14.4 kW Cabinet Size (MAX) 05 -­‐-­‐ ... TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton ... For a properly matched system and piston sizing information ... FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin Use + and - keys to zoom in and out, arrow keys move the zoomed portion of the image Use + and - keys to zoom in and out, escape key to reset, arrow keys to change image in reset state or move the zoomed portion of the image Size (tons) Nominal BTU/hr Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions ... 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER ... Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match,Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T …Heat Pumps /. Performance 4-Ton 14 SEER R410A Heat Pump (460 V 3-Phase) Need help with your order? We have the depth of experience and inventoried stock plus technical support to handle your job from the smallest to the largest! 781-322-8800.Page 1. June 2004. PISTON KIT CHART (cont'd) 2. AMANA PISTON KIT CHART VALUE LINE BAG ASSY PISTONS. Mix-Matched evaporators and Amana condensers will require piston changes as listed below: WARNING. IT IS ESSENTIAL THAT. INDOOR AND OUTDOOR SECTIONS BE PROPERLY MATCHED.Condensing Unit Air Handler / A-Coil Piston Size / TXV Valve Model SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC4018C1000AA M4CXC028BA1CAAA 051 / (MAYTXVACHP1830AA) 14 064 068, 058, 057, 050, 069, 051 YES M4CXC030BB1CAAA 051 / (MAYTXVACHP1830AA) 14 063 068, 058, 057, 064, 050,Sep 12, 2013 ... Can you install a 410a condensing unit on a r22 system. Fast Affordable Air•150K views · 4:27. Go to channel · HVAC Service Call | Clogged ... These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem. Flowcheck Pistons. Showing 1 - 12 (of 49) results. Part # 61-22119-68.R-410A 2 Ton; R-22 1.5 Ton; Piston Size 53; Specifications Product Name: Piston #53 2T R410A Brand Name: ADP Item # 100000036 Weight: 1 lbs Length: 12 in Width:goodman piston size. I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash.20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …I was thinking R22 & 3.5- 13 SEER and I am working on 4.0 - 14 SEER -R410a - That is where I screwed up! Thinking R22. Piston chart for R410A- …Cabinet Finish 4 - R-410A only U Uncased P Cased - Painted C Cased - Unpainted Expansion Device Nominal Width or f Gas Furnace F Flowrater A - 14” Width D - 24.5” Width ... Tons Connection Piston Size* (in.) Ship Weight W H A Liquid Suction (lbs) CAUF3137B6 16½" 27" 25" 2½-3 ⅜" ¾" .071 53Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort. Secure Cabinet. A galvanized, embossed, and insulated cabinet protects this coil and prevents air leakage, providing superior longevity and efficiency.Apr 4, 2016 ... If the outdoor unit manufacturer does not recommend a piston size, ... Coils are suited for R-22 and R-410A ... Fixed Orifice Charging2, 3, 4 – Use ...Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same.Be the first to ask a question about this product! Product Features. Product Detailspiston sizing is only a concern for heat pump heating operation. Follow piston change recommendations in this Guideline for proper heat pump heating operation (see Table …no warranty claim will be honored for mix-matched systems that fail to adhere to the specified piston size. warning gsx140301a* asx140301(b,c)* ssx140301(a,b)* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861 b1789865 tx3n4 tx3n4 2,3 1,3 anx140301a* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual. ... See Table 1 for factory installed piston size. Some system combinations will require a different sized ...INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5103 00 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. …Factory supplied charge R-410A; Glossy corrosion resistant finish; High pressure switch; ... Silver Series 3 Ton, 14 SEER, R410A, Air Conditioner Unit, 208-230/1/60: Item Number: 4A7A4036L1000A: ... Drain Connection Size: 3/4" Suction Line Fitting: Sweat or Braze: Suction Line Size (OD) 3/4" Liquid Line Fitting:(2) correct piston already provided on indoor coil 61000 .090 (2) (3) purchase piston kit from distributor 62000 .090 (2) (4) b17898-65 piston provided on indoor coil ae(r)60 .090 (2) (5) correct piston already provided on outdoor unit (at the liquid service valve) piston kit chart note: most units are shown as the root unit.piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Carrier tech support called and back and said, 56 or 57 - depending on what indoor coil it is. Product Data manual stated - #57 indoor piston and #46 outdoor piston (heating). If you want the manuals, let me know and I will email them to you. Instead of learning the tricks of the trade, learn the trade.INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5301 01 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. …Hydraulic Pumps - Hydraulic pumps are capable of pushing large amounts of oil through hydraulic cylinders. Learn about hydraulic pumps and hydraulic pump capabilities. Advertisemen...The orifice will need to be changed. The question is whether the evaporator is rated for the 410 pressures. In the early days the R22 evaporators could not contain R410, but after 410 came out mfg’s started making heavier coils that could support 410 but R22 was cheaper and we had experience with it so we continued using it even though it …The 3 to 15 ton Copeland Scroll Digital™ compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variableSize (tons) Nominal BTU/hr Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions ... 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER ... Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match,Piston r410a Solved 9.4 kg of r-134a fill a 0.7-m3 weighted Answer solved problem. ... 2 1/2 Ton R410A | Gemaire. Check Details. Piston Size Chart R22 Goodman - Best ...I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused.Trane 4MXCD010AC6HCA 4MXC 24-1/2 in. 3.5 - 5 Ton Convertible, Upflow, Downflow, Horizontal Left and Horizontal Right Cased Coil for Split-System Heat Pump and Split-System Air Conditioner Installation manual ... R410a piston sizes for 2.5T outdoor capacity system. Outdoor Unit Model* 4A7A3030G1. 4A7A3030H1. 4A7A4030L1. 4A7A4031L1. …Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive tBe the first to ask a question about this product! Product Features. Product Details14 seer split system air conditioner & heat pump 1.5-5 tons r410a (24 pages) Air Conditioner Trane Voyager Manual. Product (93 pages) ... * The ship-with literature bag will contain additional Outdoor Unit Piston Size* R-410A pistons for most applications. Piston Kit Capacity (Tons) (R410a) * Contact your local parts center to order the ...iPad: There are apps that are great for writing and then there are apps that great for editing. The recently updated Phraseology does both, but it really excels when you start edit...Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069Be the first to ask a question about this product! Product Features. Product Details1 3/8. 1 5/8. 1 5/8. 1 5/8. Refer to DuPont Refrigerant Expert, Version 2.0 for actual velocities and pressure drops. Equivalent length is actual length plus friction losses caused by fittings and accessories. Line sizes are expressed in outside diameter of type “L” copper tubing. Line sizes are calculated at rated full load system capacity.Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches.Flowcheck Pistons. Showing 1 - 12 (of 49) results. Part # 61-22119-68.One ton of gravel covers 100 square feet at 2 inches thick, 80 square feet at 3 inches thick, 70 square feet at 4 inches thick or 60 square feet at 5 inches thick. These stones can...CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit.At 236,857 tons, Wonder of the Seas will be nearly 4% bigger than the current size leader in the cruise world, Royal Caribbean's 3-year-old Symphony of the Seas The first voyages o...I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). ... Goodman told me to use Armstrong's piston size. My concern is the 3 ton 13 SEER coil is twice the size of the OEM. ... Just gonna have to …Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with …section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) ... (4) b17898-65 piston provided on …At 236,857 tons, Wonder of the Seas will be nearly 4% bigger than the current size leader in the cruise world, Royal Caribbean's 3-year-old Symphony of the Seas The first voyages o...Lennox Elite C35, C35-49C-2F, 4 Ton, Piston (R410A), Cased Aluminum Upflow Evaporator Coil . Lennox Elite C35, C35-49C-2F, 4 Ton, Piston (R410A), Cased Aluminum Upflow Evaporator Coil ... Dimensions. 29.5 x 21 x 22 . Family. C35 . Series. Elite . Configuration. Upflow . Nominal Cooling Capacity. 4 Ton . Metering Device. Piston … FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin Use + and - keys to zoom in and out, arrow keys move the zoomed portion of the image Use + and - keys to zoom in and out, escape key to reset, arrow keys to change image in reset state or move the zoomed portion of the image Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999Flowcheck Pistons. Showing 1 - 12 (of 49) results. Part # 61-22119-68.Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. Place Your Order by 1 pm for Same-Day Shipping3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above IndoorEven longtime industry executives are amazed at the growth. At 171,598 tons, the newest vessel from fast-growing MSC Cruises is of a size that would have been unthinkable just a co...3/4" FEMALE NPT PRIMARY & SECONDARY DRAIN CONNECTIONS (IMPORTANT: HAND TIGHTEN) SUCTION CONNECTION LIQUID CONNECTION CAPF3636C6 PISTON SECTION XSEC0002-XSEC0002 Specifications Model Cabinet Dimensions Nominal Tons Connection Piston Size* (in.) Ship Weight W D H Liquid Suction (lbs) CAPF3137B6 17½" 21" 30" 2½-3 ⅜" ¾" .071 53

Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately. Quest 14th street

4 ton 410a piston size

Be the first to ask a question about this product! Product Features. Product Details NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston Size Piston P/N Note TXV Kit P/N (if used) Outdoor Unit GSX140421A* ASX140421(C,D)* SSX140421(B,C)* All AHRI Matches 0.070 B1789870 TX5N4 1,3 ANX140421A* All AHRI Matches 0.074 B1789874 TX5N4 1,3 Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative).Trane 4MXCD010AC6HCA 4MXC 24-1/2 in. 3.5 - 5 Ton Convertible, Upflow, Downflow, Horizontal Left and Horizontal Right Cased Coil for Split-System Heat Pump and Split-System Air Conditioner Installation manual ... R410a piston sizes for 2.5T outdoor capacity system. Outdoor Unit Model* 4A7A3030G1. 4A7A3030H1. 4A7A4030L1. 4A7A4031L1. … Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069 3.5 Ton, 4 Ton : Product Width (in) 17.5 : Line Set Connection Type: Sweat : Liquid Line Size: 3/8 inch : Weight (lbs) 66.000000 : Refrigerant: R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNINGAdvertisement We don't often realize how much untapped energy exists all around us. The principle behind these manhole explosions is similar to how a car engine works. Imagine a ci...Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...Size (tons) Nominal BTU/hr Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions ... 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER ... Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match,Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...4 physical data unit size 024 030 036 042 048 060 nominal capacity (ton) 2 2.5 3 3.5 4 5 shipping weight (lb) (kg) 312 142 333 151 334 152 388 177 407 185 475 215 compressor type scroll refrigerant r-410a refrigerant quantitiy (lb) quantity (kg) 6.3 2.9 9.8 3.1 6.8 3.1 7.7 3.5 9.0 4.1 12.0 5.4 outdoor metering device txv piston txv piston ...Flowcheck Pistons. Showing 1 - 12 (of 49) results. Part # 61-22119-68.Messaging service Telegram said on Tuesday it is abandoning its blockchain platform Telegram Open Network (TON) after a lengthy battle with the U.S. Securities and Exchange Commiss...DISCHARGE LINE SIZE COMPRESSOR TO CONDENSER 1F° (5 PSI pressure drop maximum) LIQUID CONDENSATE LINE CONDENSER TO RECEIVER Condensate drain / vent. System Capacity BTU/Hr. System Capacity Tons/Hr. Equivalent Line Lengths (feet) Equivalent Line Lengths (feet) 25. 50. 75. 100. 150. 25. 50. 75. 100. 150Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately Sx.e Vendor: ADVANCED DISTRIBUTOR PRODUCTS. Advanced Distributor Products #53, Florator Piston for 1.5 Ton R-22 and 2 Ton R-410A Air Handler Evaporator Coil. Specifications. Size: #53. Used On Item: 1.5 Ton R22, 2 Ton R410A Air Handler Evaporator Coil. Used On Model/Brand: 18, 24. QTY. Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separatelyLennox Elite CH23, CH23-51 Coil, 4 Ton, Piston (R410A), Cased Copper Horizontal Evaporator Coil . Lennox Elite CH23, CH23-51 Coil, 4 Ton, Piston (R410A), Cased Copper Horizontal Evaporator Coil ... Dimensions. 23 x 10 x 35 . Family. CH23 . Series. Elite . Configuration. Horizontal . Nominal Cooling Capacity. 4 Ton . Metering Device. Piston ...piston kit chart (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested conmination indoor unit. all other indoor combinations, piston must be purchased from distruibutor. (3) txv must be purchased separately. pkcg-4001zb february 2020 ^ ] Ì e } Description Piston Size. Part Number. Qty; For Coils Size (MBTUH) 41 176799941. 10. 12; ... standard R-22 and R-410A pistons listed above (100 pistons total) in a ... .